Power range1 3.5 - 30 kW. New heating elements groups are purchased in the Czech Republic, at the Backer plant. This allows and allows the use of both water and antifreeze liquids.
Thanks to the installation of an electronic thermostat, the range of adjustment of the coolant temperature became from +5 to +85 degrees, while its adjustment can be maintained with an accuracy of one degree. Temperature settings from +5 degrees allow connecting the “anti-freeze” function with minimum consumption electrical energy.
WARMOS-IV is controlled via an LED display with a membrane keyboard that replaces key switches. In the new Varmos, design changes were made in terms of installation electronic system thermoregulation, which replaced mechanical thermostat. With a temperature sensor, the electric boiler is able to automatically select the number of stages for optimal performance in system. Three stages, each of them 1/3 power.
Rotation of work of heating elements groups. The heating elements are not rigidly tied to the steps. There is a constant change in the switching position of the heating elements. Thus, the load on heating elements spreads equally.
The display shows the coolant temperature from 0 to +90 degrees. And when starting the boiler with a temperature below zero degrees, -0 will appear on the display, which will useful information for the consumer. But this function is only available when using antifreeze fluid in the system.
The manufacturer guarantees stable work with a power supply deviation of +-10%. The Varmos 4 boiler has connections for circulation pump and an air temperature sensor. Thanks to the appearance of a light display on the front of the device, it also became possible to display an indication of errors that occur during operation of the boiler in the form of codes.
Warranty for this the lineup is 2 years, all boilers have the necessary certificates and are tested at special stands at the factory.
Increased temperature Range
WARMOS-IV operates in an extended coolant temperature range from +5 to +85°C. Thanks to this, you can additionally use it in such modes as: “Warm floor” and “Anti-freeze”:
In mode "Warm floor" WARMOS-IV is directly connected to the underfloor heating system.
In mode “Antifreeze” the boiler saves energy by operating from +5 to +15°C. This is convenient when people leave the premises for a long time.
New design and indicators
New design WARMOS complemented by an improved control panel with LED indication. Bright indicators show power levels and coolant temperature. If the boiler starts at a negative temperature, a special value is displayed: “-0”. The “Boiler control based on room air temperature” mode is displayed on the indicator by a flashing dot. Indication of emergency situations is provided.
Ease of operation and maintenance of the boiler
WARMOS-IV cares about your convenience and safety. If an emergency situation occurs on the panel codes are displayed, which signal if:
✓
the thermal sensor for monitoring the coolant temperature has broken (code E1);
✓
It happened short circuit temperature control temperature sensor (E2);
✓
the coolant has warmed up above +84°C (E3);
✓
the coolant has heated up above +90°C (FF).
Additional safety is provided by an independent circuit emergency shutdown
You can easily set the desired coolant temperature from +5 to +85°C with an accuracy of 1 degree. The selection of power levels occurs automatically - the boiler itself determines optimal number steps. At the same time, the possibility of manual power control remains.
The boiler is resistant to voltage surges in the network and remains operational both at low (up to 180 V) and at high (up to 260 V) voltage.
Besides, WARMOS-IV has all the advantages characteristic of other EVAN electric boiler models: the ability to use water and non-freezing liquids as a coolant, the option of a time delay for turning on and off power levels, reliable heating elements made of of stainless steel produced by Backer with their rotation every time you turn it on.
Show in full Collapse description
Technical characteristics Electric boiler EVAN Warmos- IV 30
Evan Warmos-IV-6 is the latest model in the line of electric heating boilers of the Warmos series. The boiler has wider functionality compared to previous models: a wider temperature selection range (from 5 to 85 degrees). Due to the reduction minimum temperature up to 5 degrees appeared to work directly with warm floors, bypassing the various contours of the mixture.
Among other things, the boiler is equipped with safety systems traditional for European equipment: protection against freezing and overheating, short circuit. Unlike its European counterparts, the Evan Warmos-IV-6 boiler can be started at sub-zero temperatures.
As usual, it is possible to connect , or .
Naturally, the design has been updated, and now this equipment is in no way inferior in appearance to the European manufacturer. Due to the fact that the boiler is produced for domestic consumers, the equipment is resistant to voltage surges, the manufacturer allows the use of not only water as a coolant, but also (anti-freezing liquids), smooth power adjustment and the inclusion of heating elements, which are made of high-quality stainless steel (Backer) with rotating them every time you turn them on and off.
WARMOS-IV-6 is the new generation of the WARMOS family. What makes it different from its predecessors?
Increased temperature range
WARMOS-IV-6 operates in an extended coolant temperature range from +5 to +85°C. Thanks to this, you can additionally use it in such modes as: “Warm floor” and “Anti-freeze”:
In the “Warm Floor” mode, WARMOS-IV is directly connected to the floor heating system.
In the “Anti-freeze” mode, the boiler saves energy by operating from +5 to +15°C. This is convenient when people leave the premises for a long time.
New design and indicators
The design of the new WARMOS is complemented by an improved control panel with LED indication. Bright indicators show power levels and coolant temperature. If the boiler starts at a negative temperature, a special value is displayed: “-0”. The “Boiler control based on room air temperature” mode is displayed on the indicator by a flashing dot. Indication of emergency situations is provided.
Ease of operation and maintenance of the boiler
WARMOS-IV cares about your convenience and safety. If an emergency situation occurs, codes are displayed on the panel that signal if:
the thermal sensor for monitoring the coolant temperature has broken (code E1);
a short circuit occurred in the temperature control temperature sensor (E2);
the coolant has warmed up above +84°C (E3);
the coolant has heated up above +90°C (FF).
Additional safety is provided by an independent emergency shutdown circuit
You can easily set the desired coolant temperature from +5 to +85°C with an accuracy of 1 degree. The selection of power stages occurs automatically - the boiler itself determines the optimal number of stages. At the same time, the possibility of manual power control remains.
The boiler is resistant to voltage surges in the network and remains operational both at low (up to 160 V) and at high (up to 260 V) voltage.
In addition, WARMOS-IV has all the advantages characteristic of other EVAN electric boiler models: the ability to use water and non-freezing liquids as a coolant, the option of a time delay for turning on and off power levels, reliable stainless steel heating elements made by Backer with their rotation every time you turn them on.
WARMOS-IV 6 ELECTRIC BOILER EVAN
WARMOS-IV is a new generation electric heating boiler of the WARMOS family. What makes it different from its predecessors?
Increased temperature range
WARMOS-IV operates in an extended range from +5 to +85°C. Thanks to this, you can additionally use it in such modes as: “Warm floor” and “Anti-freeze”:
In the “Warm Floor” mode, WARMOS-IV is directly connected to the floor heating system.
In the “Anti-freeze” mode, the boiler saves energy by operating from +5 to +15°C. This is convenient when people leave the premises for a long time.
New design and indicators
The design of the new WARMOS is complemented by an improved control panel with LED indication. Bright indicators show power levels and coolant temperature. In this case, when the boiler starts at a negative temperature, a special value is displayed: “-0”. The “Boiler control based on room air temperature” mode is displayed on the indicator by a flashing dot. Indication of emergency situations is provided.
Ease of operation and maintenance of the boiler
WARMOS-IV cares about your convenience and safety. If an emergency situation occurs, codes are displayed on the panel that signal if:
the thermal sensor for monitoring the coolant temperature has broken (code E1);
a short circuit occurred in the temperature control temperature sensor (E2);
the coolant has warmed up above +84°C (E3);
the coolant has heated up above +90°C (FF).
Additional safety is provided by an independent emergency shutdown circuit
You can easily set the desired coolant temperature from +5 to +85°C with an accuracy of 1 degree. The selection of power stages occurs automatically - the boiler itself determines the optimal number of stages. At the same time, the possibility of manual power control remains.
In addition, WARMOS-IV has all the advantages characteristic of other EVAN electric boiler models: resistance to electrical fluctuations, the ability to use water and non-freezing liquids as a coolant, a time delay option for turning on and off power levels, reliable stainless steel heating elements made by Backer with rotation them every time you turn on and so on.
1 - boiler
2 - inlet pipe G 1¼
3 - outlet G 1¼
4 - heating element with stainless steel tubes
5 - rear panel
6 - screw clamp
7 - network cable and clamp for protective conductor RE
8 - screw clamp for connecting the circulation pump and air temperature sensor
9 - contactor for emergency shutdown of the heating element (for W-7.5-12)
10 - control unit with membrane keyboard and cable
11 - circuit fuse for connecting the circulation pump
12 - membrane keyboard and cable
Delivery terms
Within the Moscow Ring Road:
- 0 rub. (for orders over RUB 10,000);
- 300 rub. (for orders from 5,000 to 10,000 rubles);
- 600 rub. (order worth less than RUB 5,000).
Outside the Moscow Ring Road:
- 0 rub. up to 10 km (orders worth more than 20,000 rubles);
- more than 10 km from the Moscow Ring Road - check with a consultant.
Transportation within the Russian Federation:
The cost of delivery to the regions is in accordance with the tariff chosen by the customer, subject to 100% prepayment.
Products are dispatched with prepayment after receipt of payment on the account. All necessary financial documents are sent along with the order.
Please note: we are not responsible for damage to goods that occurred due to the fault of postal services.
More detailed information according to the terms of "Delivery".
Exchange and return of products are carried out in accordance with the law Russian Federation in the field of consumer protection.
Basic provisions
You can, within 7 days, starting from the date of purchase, return a product of proper quality if it has not been used, its presentation (labels, packaging, seals), consumer qualities, as well as documentation confirming the fact and conditions of purchase of the specified product have been preserved. goods (cash or sales receipt). You must also present identification.
Products of good quality cannot be exchanged:
- having individually defined properties, if the purchased product can only be used by a certain buyer;
- indicated in the List of products (non-food) of proper quality that are not subject to exchange/return, approved by Decree of the Government of the Russian Federation (No. 55, 01/19/1998).
Claims regarding an order/product of inadequate quality:
Returns and exchanges of such products are also carried out within 7 days. This period is counted from the moment of delivery of the goods. The product must not be used appearance must be saved. In addition, you need a document confirming the purchase of the goods.
WARMOS-IV is a new generation electric heating boiler of the WARMOS family. What makes it different from its predecessors?
Increased temperature range
WARMOS-IV operates in an extended coolant temperature range from +5 to +85°C. Thanks to this, you can additionally use it in such modes as: “Warm floor” and “Anti-freeze”:
- In the “Warm Floor” mode, WARMOS-IV is directly connected to the floor heating system.
In the “Anti-freeze” mode, the boiler saves energy by operating from +5 to +15°C. This is convenient when people leave the premises for a long time.
New design and indicators
The design of the new WARMOS is complemented by an improved control panel with LED indication. Bright indicators show power levels and coolant temperature. If the boiler starts at a negative temperature, a special value is displayed: “-0”. The “Boiler control based on room air temperature” mode is displayed on the indicator by a flashing dot. Indication of emergency situations is provided.
Ease of operation and maintenance of the boiler
WARMOS-IV cares about your convenience and safety. If an emergency situation occurs, codes are displayed on the panel that signal if:
the thermal sensor for monitoring the coolant temperature has broken (code E1);
a short circuit occurred in the temperature control temperature sensor (E2);
the coolant has warmed up above +84°C (E3);
the coolant has heated up above +90°C (FF).
Additional safety is provided by an independent emergency shutdown circuit
You can easily set the desired coolant temperature from +5 to +85°C with an accuracy of 1 degree. The selection of power stages occurs automatically - the boiler itself determines the optimal number of stages. At the same time, the possibility of manual power control remains.
The boiler is resistant to voltage surges in the network and remains operational both at low (up to 160 V) and at high (up to 260 V) voltage.
In addition, WARMOS-IV has all the advantages characteristic of other EVAN electric boiler models: the ability to use water and non-freezing liquids as a coolant, the option of a time delay for turning on and off power levels, reliable stainless steel heating elements made by Backer with their rotation every time you turn them on.
1 - boiler
2 - inlet pipe G 1¼
3 - outlet G 1¼
4 - heating element with stainless steel tubes
5 - rear panel
6 - screw clamp
7 - network cable and clamp for the protective conductor PE
8 - screw clamp for connecting the circulation pump and air temperature sensor
9 - contactor for emergency shutdown of the heating element (for W-7.5-12)
10 - control unit with membrane keyboard and cable
11 - circuit fuse for connecting the circulation pump
12 - membrane keyboard and cable