Buderus Logano G234 WS-50 kW Floor-standing gas boiler, cast iron, atmospheric burner

Logano G234 WS

  • Boiler block design with perfectly matched sections
  • Boiler sections made of high quality cast iron GL 180 M
  • Combustion chamber closed on all sides
  • Intensive heat transfer of heating surfaces thanks to special fins
  • Easy installation and maintenance thanks to simple design
  • Fully automatic operation with electric ignition, no additional gas consumption required for ignition
  • To make it easy to connect gas to the boiler at the back, there is a gas pipeline under its casing.
  • Thermal insulation 80 mm thick. reduces heat loss to a minimum
  • The heating boiler is completely assembled together with the casing - this saves time and installation costs
  • Compact dimensions - an advantage when carried through openings and when placed in a boiler room
  • Various combinations with control systems and cylinders - to suit every need
  • Large selection of additional equipment for quick installation, adapted to a specific boiler
Gas burner with pre-mix
  • Fully automatic burner with electric ignition
  • Ionization flame control and double magnetic valve
  • The Venturi tube of a gas burner ensures mixing of fuel with air. During the combustion process, many small individual flames are formed without a high-temperature core. Therefore, in such gas burners the combustion temperature is significantly reduced. In addition, the short flame of these fireplaces easily breaks away from the burner rod, reducing the heat load on it
Supply
  • Heating boiler - for operation on natural gas H, with thermal insulation and boiler casing - 1 box
  • Conversion kit for liquefied gas P and B/P (additional equipment) - 1 box
  • Control system (optional) - 1 box

Flue gas temperature / chimney connection
The required pressure is for all boiler sizes a minimum of 3 and a maximum of 10 Pa.
For more precise adjustment and maintenance of draft in the chimney, as well as for organizing ventilation of the chimney itself, it is recommended to install and adjust an additional air regulator (draft limiter). The cross-section of the additional air regulator depends on the effective height and cross-section of the chimney.

Flue gas shut-off valve
If desired, a flue gas shut-off valve can be purchased as an additional order. A flue gas shut-off valve installed before the draft breaker is more effective than one installed after it.

Installations with underfloor heating
In floor heating systems using oxygen-permeable plastic pipes (DIN 4726), it is necessary to install a heat exchanger between the boiler and the floor heating system.

Preparing hot water
The heating boiler can work with any water heater tank. Combinations of the boiler with tanks of the Logalux ST/SU series have particular advantages.

General provisions

  • For heating boilers that must be equipped with a flue gas monitoring system according to the FeuVO of the relevant federal state, accessories can be supplied
  • For version B11 (without flue gas monitoring system), the boiler may only be installed in rooms that have the required ventilation to the atmosphere and also have a self-closing and sealed door, for example in boiler rooms
  • For version B11 BS (with flue gas monitoring system), the heating boiler can be installed in apartments or similar places
  • To ensure the functioning of the boiler, all connections must be made in the places specified for them
  • When installing a gas heating boiler operating on liquefied gas below ground level, it is recommended to install a second solenoid valve. A switchgear for controlling the solenoid valve can be supplied as an option
  • In installations with underfloor heating, with several heating circuits, as well as in installations with large water volumes, it is necessary to install a mixer to regulate the heating circuits, based on local operating conditions.
Inspections
To ensure environmentally friendly and trouble-free operation, we recommend regular inspections of the boiler and burner.

When installing the heating boiler, the minimum distances shown (indicated in parentheses) must be observed. For ease of installation, servicing and maintenance, it is necessary to maintain the recommended distances from the walls.
The room for installing equipment must be protected from the cold and have good ventilation. In addition, care must be taken to ensure that the combustion air is not contaminated with dust or halogenated hydrocarbons. Halogenated hydrocarbons of all types are found, for example, in aerosol cans, solvents and cleaners, varnishes, paints and adhesives.

Modern universal boiler concept

  • Low temperature heating boiler according to DIN EN 297 with continuously variable boiler water temperature control without base temperature (minimum boiler water temperature)
  • Four certified boiler sizes with a nominal heating output of 38-55 kW
  • The heating boiler is designed to operate on natural gas H and liquefied gas P / B / P
  • Boiler design with perfectly fitted sections made of high-quality cast iron
  • Tested and reliable heating boiler with cast iron heat exchanger and atmospheric gas burner
  • Combines with adjacent Logalux ST and Logalux SU water heater tanks from the Buderus program
  • Can be combined with various control systems from the Buderus program
  • High standardized utilization rate (93%) and low emissions of harmful substances
Quiet and reliable operation
  • Atmospheric gas burner with pre-mixing without fan
  • Heating mode without additional noise reduction measures
  • Stable operation on natural gas with supply pressure up to 10 mbar
Simple and convenient control
  • Control functions coordinated with the plant hydraulics
  • Easy setup of all control system functions (Push and Turn principle)
  • It is possible to expand the configuration of all control systems for additional modules
Fast installation, commissioning and maintenance
  • A system for quickly installing the heating circuit, adapted to the corresponding hydraulic circuit, for connecting it to the boiler or mounting it to the wall
  • Convenient connection of Logalux ST and Logalux SU water heater tanks with a capacity of 150, 160, 200 and 300 liters to the boiler thanks to the boiler-water heater connecting pipeline with loading pump and check valve
  • Burner design without moving parts
  • Easy conversion of the burner to other types of gas

Equipped with an atmospheric burner, the Buderus Logano G234-50 WS floor-standing cast iron gas boiler with a power of 50 kW is intended for heating residential and non-residential buildings and premises with a total area of ​​up to 500 square meters. meters (a more accurate calculation of the maximum area is carried out by designers of heating and gas supply systems). The concept of the boiler operation is such that it can operate in heating mode without maintaining the base temperature (lower temperature of the boiler water), which makes it possible to seriously optimize the entire process of system operation and seriously increase the actual efficiency of the boiler (up to 93%). If necessary, it can be converted from natural gas to liquefied gas and vice versa. To do this, it is necessary to additionally purchase an internal gas pressure monitoring device (regulator) for each physical state of the fuel. The structure of the Buderus Logano G234-50 WS boiler is shown in Figure 1.

Equipped with a cast iron heat exchanger, the Buderus Logano G234-50 WS boiler is additionally equipped with Logalux water heater tanks, which are mounted next to the boiler. It is not possible to install the boiler on top of the tank. Thanks to the atmospheric burner, the requirements for gas quality indicators are reduced, which allows you to create a gas-air mixture of the required parameters even at very low pressure in the gas pipeline.

Installation and Operation Basics

The Buderus Logano G234-50 WS boiler is installed exclusively in boiler rooms and furnace rooms equipped with a window opening with an area of ​​at least 400 sq.cm. Also, the premises must be equipped with an active ventilation and smoke duct with a cross-sectional area of ​​150 sq.cm, and have a room volume of at least 15 cubic meters. If a filter and (or) grille is installed on the inlet, then the cross-sectional diameter must be increased to the next standard size in the range.

It is prohibited to install the boiler in walk-through combustion chambers. Also, the room must be well protected from the cold (maximum permissible boiler operating temperature + 5°C). When constructing the foundation of the combustion area, in addition to the volumetric requirements, the following distances must be maintained (excluding the heater tank):

All automation and operating principles of the Buderus Logano G234-50 WS boiler with an open combustion chamber are quite simple. However, during installation, connection to networks and first start-up, under no circumstances should you install the boiler yourself. Entrust the work to specialized service centers and certified specialists. Also, during installation and operation, make sure that only original Buderus brand parts are used.

Where is the Buderus Logano G234-50 WS boiler used?

Country houses and cottages. The powerful Buderus Logano G234-50 WS boiler can easily cope with heating a cottage or country house with an area of ​​up to 500 sq.m. subject to excellent insulation. To organize hot water supply, it is possible to pair the device with an indirect heating boiler and an automatic three-way tap.

Warehouses, industrial premises, shops, service facilities, catering. The cast iron boiler Buderus Logano G234-50 WS is also perfect for semi-industrial purposes, when the construction of a mini-boiler house is not economically viable, and feeding the heating network from a centralized heating system is impossible, difficult or impractical.

If there is a lack of power, it is possible to use a cascade system of Buderus Logano G234-50 WS boilers with an integrated smoke exhaust system. In this case, one of the boilers will be almost constantly in reserve, which will make the heating process guaranteed uninterrupted and protect against possible depressurization in the event of malfunctions during sub-zero temperatures.

Atmospheric gas boiler Buderus Logano G234-50 WS, G20

Floor-standing gas cast iron heating boilers Buderus Logano G234WS with an atmospheric burner with a power of 38, 44, 50, 55 kW.
A new generation of time-tested boilers with modern EMS Plus automation and industrial design from Buderus.

Modern universal boiler concept Buderus Logano G234 WS

  • Low-temperature heating boiler according to DIN EN 297 for continuously regulating the boiler water temperature without a base temperature (minimum boiler water temperature)
  • Four certified boiler sizes with rated heating output from 38 to 55 kW
  • The heating boiler is designed to operate on natural gas H or liquefied gas P /B/P
  • Boiler design with perfectly fitted sections made of high-quality cast iron
  • Tested and reliable heating boiler with cast iron heat exchanger and atmospheric gas burner
  • Combines with adjacent Logalux SU water heater tanks from the Buderus program
  • Can be combined with various EMS and EMS Plus control systems from the Buderus program
  • New "industrial" design from Buderus
  • High standardized utilization rate (92%) and low emissions of harmful substances

Quiet and reliable operation

  • Atmospheric gas burner with pre-mixing without fan
  • Heating mode without additional noise reduction measures
  • Stable operation on natural gas with supply pressure up to 10 mbar

Simple and convenient control with modern weather-compensated automation Logamatic MC110 standard EMS Plus

  • System controller RC310 or BC30E with touch display and full text menu
  • Readable text, symbols, status and error information
  • Control functions coordinated with the plant hydraulics
  • Simple step-by-step and intuitive setup of all control system functions
  • It is possible to expand the configuration of the control system with additional modules:
  • KM200 module for remote control via the Internet
  • Mixing module MM100
  • Cascade module MC400 with the ability to control up to 4 boilers
  • For complex systems, we recommend using the new generation of professional automation Logamatic 5000

Quick installation, commissioning and maintenance of the Buderus Logano G234WS boiler

  • A system for quickly installing the heating circuit, adapted to the corresponding hydraulic circuit, for connecting it to the boiler or mounting it to the wall
  • Convenient connection of Logalux SU water heater tanks with a capacity of 120, 160, 200 and 300 liters to the boiler thanks to the boiler-water heater connecting pipeline with loading pump and check valve
  • Burner design without moving parts
  • Easy conversion of the burner to other types of gas


This article is also available in the following languages: Thai

  • Next

    THANK YOU so much for the very useful information in the article. Everything is presented very clearly. It feels like a lot of work has been done to analyze the operation of the eBay store

    • Thank you and other regular readers of my blog. Without you, I would not be motivated enough to dedicate much time to maintaining this site. My brain is structured this way: I like to dig deep, systematize scattered data, try things that no one has done before or looked at from this angle. It’s a pity that our compatriots have no time for shopping on eBay because of the crisis in Russia. They buy from Aliexpress from China, since goods there are much cheaper (often at the expense of quality). But online auctions eBay, Amazon, ETSY will easily give the Chinese a head start in the range of branded items, vintage items, handmade items and various ethnic goods.

      • Next

        What is valuable in your articles is your personal attitude and analysis of the topic. Don't give up this blog, I come here often. There should be a lot of us like that. Email me I recently received an email with an offer that they would teach me how to trade on Amazon and eBay.

  • And I remembered your detailed articles about these trades. area
    I re-read everything again and concluded that the courses are a scam. I haven't bought anything on eBay yet. I am not from Russia, but from Kazakhstan (Almaty). But we also don’t need any extra expenses yet.