Buderus Logano G234 WS-50 kW Floor-standing gas boiler, cast iron, atmospheric burner
Logano G234 WS
- Boiler block design with perfectly matched sections
- Boiler sections made of high quality cast iron GL 180 M
- Combustion chamber closed on all sides
- Intensive heat transfer of heating surfaces thanks to special fins
- Easy installation and maintenance thanks to simple design
- Fully automatic operation with electric ignition, no additional gas consumption required for ignition
- To make it easy to connect gas to the boiler at the back, there is a gas pipeline under its casing.
- Thermal insulation 80 mm thick. reduces heat loss to a minimum
- The heating boiler is completely assembled together with the casing - this saves time and installation costs
- Compact dimensions - an advantage when carried through openings and when placed in a boiler room
- Various combinations with control systems and cylinders - to suit every need
- Large selection of additional equipment for quick installation, adapted to a specific boiler
- Fully automatic burner with electric ignition
- Ionization flame control and double magnetic valve
- The Venturi tube of a gas burner ensures mixing of fuel with air. During the combustion process, many small individual flames are formed without a high-temperature core. Therefore, in such gas burners the combustion temperature is significantly reduced. In addition, the short flame of these fireplaces easily breaks away from the burner rod, reducing the heat load on it
- Heating boiler - for operation on natural gas H, with thermal insulation and boiler casing - 1 box
- Conversion kit for liquefied gas P and B/P (additional equipment) - 1 box
- Control system (optional) - 1 box
Flue gas temperature / chimney connection
The required pressure is for all boiler sizes a minimum of 3 and a maximum of 10 Pa.
For more precise adjustment and maintenance of draft in the chimney, as well as for organizing ventilation of the chimney itself, it is recommended to install and adjust an additional air regulator (draft limiter). The cross-section of the additional air regulator depends on the effective height and cross-section of the chimney.
Flue gas shut-off valve
If desired, a flue gas shut-off valve can be purchased as an additional order. A flue gas shut-off valve installed before the draft breaker is more effective than one installed after it.
Installations with underfloor heating
In floor heating systems using oxygen-permeable plastic pipes (DIN 4726), it is necessary to install a heat exchanger between the heating boiler and the floor heating system.
Preparing hot water
The heating boiler can work with any water heater tank. Combinations of the boiler with tanks of the Logalux ST/SU series have particular advantages.
General provisions
- For heating boilers that must be equipped with a flue gas monitoring system according to the FeuVO of the relevant federal state, accessories can be supplied
- For version B11 (without flue gas monitoring system), the boiler may only be installed in rooms that have the required ventilation to the atmosphere and also have a self-closing and sealed door, for example in boiler rooms
- For version B11 BS (with flue gas monitoring system), the heating boiler can be installed in apartments or similar places
- To ensure the functioning of the boiler, all connections must be made in the places specified for them
- When installing a gas heating boiler operating on liquefied gas below ground level, it is recommended to install a second solenoid valve. A switchgear for controlling the solenoid valve can be supplied as an option
- In installations with underfloor heating, with several heating circuits, as well as in installations with large water volumes, it is necessary to install a mixer to regulate the heating circuits, based on local operating conditions.
To ensure environmentally friendly and trouble-free operation, we recommend regular inspections of the boiler and burner.
When installing the heating boiler, the minimum distances shown (indicated in parentheses) must be observed. For ease of installation, servicing and maintenance, it is necessary to maintain the recommended distances from the walls.
The room for installing equipment must be protected from the cold and have good ventilation. In addition, care must be taken to ensure that the combustion air is not contaminated with dust or halogenated hydrocarbons. Halogenated hydrocarbons of all types are found, for example, in aerosol cans, solvents and cleaners, varnishes, paints and adhesives.
Modern universal boiler concept
- Low temperature heating boiler according to DIN EN 297 with continuously variable boiler water temperature control without base temperature (minimum boiler water temperature)
- Four certified boiler sizes with a nominal heating output of 38-55 kW
- The heating boiler is designed to operate on natural gas H and liquefied gas P / B/P
- Boiler design with perfectly fitted sections made of high-quality cast iron
- Tested and reliable heating boiler with cast iron heat exchanger and atmospheric gas burner
- Can be combined with adjacent Logalux ST and Logalux SU water heater tanks from the Buderus program
- Can be combined with various control systems from the Buderus program
- High standardized utilization rate (93%) and low emissions of harmful substances
- Atmospheric gas burner with pre-mixing without fan
- Heating mode without additional noise reduction measures
- Stable operation on natural gas with supply pressure up to 10 mbar
- Control functions coordinated with the plant hydraulics
- Easy setup of all control system functions (Push and Turn principle)
- It is possible to expand the configuration of all control systems for additional modules
- A system for quickly installing the heating circuit, adapted to the corresponding hydraulic circuit, for connecting it to the boiler or mounting it to the wall
- Convenient connection of Logalux ST and Logalux SU water heater tanks with a capacity of 150, 160, 200 and 300 liters to the boiler thanks to the boiler-water heater connecting pipeline with loading pump and check valve
- Burner design without moving parts
- Easy conversion of the burner to other types of gas
Article: 8732204653
Documentation
Installation and maintenance instructions Logano G234 WS | 2.08 MB | |
Operating instructions Logano G234 WS | 460 KB | |
Technical data sheet Logano G234 WS | 324 KB | |
Installation instructions for a gas pressure monitoring device | 180 KB | |
Certificate of Conformity | 1.29 MB |
Logano G234 WS
- Boiler block design with perfectly matched sections
- Boiler sections made of high quality cast iron GL 180 M
- Combustion chamber closed on all sides
- Intensive heat transfer of heating surfaces thanks to special fins
- Easy installation and maintenance thanks to simple design
- Fully automatic operation with electric ignition, no additional gas consumption required for ignition
- To make it easy to connect gas to the boiler at the back, there is a gas pipeline under its casing.
- Thermal insulation 80 mm thick. reduces heat loss to a minimum
- The heating boiler is completely assembled together with the casing - this saves time and installation costs
- Compact dimensions - an advantage when carried through openings and when placed in a boiler room
- Various combinations with control systems and cylinders - to suit every need
- Large selection of additional equipment for quick installation, adapted to a specific boiler
- Fully automatic burner with electric ignition
- Ionization flame control and double magnetic valve
- The Venturi tube of a gas burner ensures mixing of fuel with air. During the combustion process, many small individual flames are formed without a high-temperature core. Therefore, in such gas burners the combustion temperature is significantly reduced. In addition, the short flame of these fireplaces easily breaks away from the burner rod, reducing the heat load on it
- Heating boiler - for operation on natural gas H, with thermal insulation and boiler casing - 1 box
- Conversion kit for liquefied gas P and B/P (additional equipment) - 1 box
- Control system (optional) - 1 box
Hydraulic resistance of the boiler through water
Fuel
The gas burners are factory set for natural gas H, comparable to the EE-H method. You can change the gas type to liquefied P/B/P at any time using the conversion parts. Conversion to city gas is not possible. The supplied gas pressure (supplied pressure is the static excess pressure of the gas relative to atmospheric pressure when it flows out at the connection point of the gas appliance) must be in the following range:
1) - Up to 8 mbar when working with a gas pressure monitoring device
The maximum supply pressure when operating on natural gas can be 25 mbar. If the supplied gas pressure is higher, it is necessary to install an additional gas pressure regulator on the burner. The maximum test pressure is 150 mbar.
Flue gas temperature / chimney connection
The required pressure is for all boiler sizes a minimum of 3 and a maximum of 10 Pa.
For more precise adjustment and maintenance of draft in the chimney, as well as for organizing ventilation of the chimney itself, it is recommended to install and adjust an additional air regulator (draft limiter). The cross-section of the additional air regulator depends on the effective height and cross-section of the chimney.
Flue gas shut-off valve
If desired, a flue gas shut-off valve can be purchased as an additional order. A flue gas shut-off valve installed before the draft breaker is more effective than one installed after it.
Installations with underfloor heating
In floor heating systems using oxygen-permeable plastic pipes (DIN 4726), it is necessary to install a heat exchanger between the heating boiler and the floor heating system.
Preparing hot water
The heating boiler can work with any water heater tank. Combinations of the boiler with tanks of the Logalux ST/SU series have particular advantages.
General provisions
- For heating boilers that must be equipped with a flue gas monitoring system according to the FeuVO of the relevant federal state, accessories can be supplied
- For version B11 (without flue gas monitoring system), the boiler may only be installed in rooms that have the required ventilation to the atmosphere and also have a self-closing and sealed door, for example in boiler rooms
- For version B11 BS (with flue gas monitoring system), the heating boiler can be installed in apartments or similar places
- To ensure the functioning of the boiler, all connections must be made in the places specified for them.
- When installing a gas heating boiler operating on liquefied gas below ground level, it is recommended to install a second solenoid valve. A switchgear for controlling the solenoid valve can be supplied as an option
- In installations with underfloor heating, with several heating circuits, as well as in installations with large water volumes, it is necessary to install a mixer to regulate the heating circuits, based on local operating conditions.
To ensure environmentally friendly and trouble-free operation, we recommend regular inspections of the boiler and burner.
Boiler installation room
When installing the heating boiler, the minimum distances shown (indicated in parentheses) must be observed. For ease of installation, servicing and maintenance, it is necessary to maintain the recommended distances from the walls.
The room for installing equipment must be protected from the cold and have good ventilation. In addition, care must be taken to ensure that the combustion air is not contaminated with dust or halogenated hydrocarbons. Halogenated hydrocarbons of all types are found, for example, in aerosol cans, solvents and cleaners, varnishes, paints and adhesives.
Modern universal boiler concept
- Low temperature heating boiler according to DIN EN 297 with continuously variable boiler water temperature control without base temperature (minimum boiler water temperature)
- Four certified boiler sizes with a nominal heating output of 38-55 kW
- The heating boiler is designed to operate on natural gas H and liquefied gas P / B/P
- Boiler design with perfectly fitted sections made of high-quality cast iron
- Tested and reliable heating boiler with cast iron heat exchanger and atmospheric gas burner
- Can be combined with adjacent Logalux ST and Logalux SU water heater tanks from the Buderus program
- Can be combined with various control systems from the Buderus program
- High standardized utilization rate (93%) and low emissions of harmful substances
- Atmospheric gas burner with pre-mixing without fan
- Heating mode without additional noise reduction measures
- Stable operation on natural gas with supply pressure up to 10 mbar
- Control functions coordinated with the plant hydraulics
- Easy setup of all control system functions (Push and Turn principle)
- It is possible to expand the configuration of all control systems for additional modules
- A system for quickly installing the heating circuit, adapted to the corresponding hydraulic circuit, for connecting it to the boiler or mounting it to the wall
- Convenient connection of Logalux ST and Logalux SU water heater tanks with a capacity of 150, 160, 200 and 300 liters to the boiler thanks to the boiler-water heater connecting pipeline with loading pump and check valve
- Burner design without moving parts
- Easy conversion of the burner to other types of gas
Floor-standing gas cast iron heating boilers Buderus Logano G234WS with an atmospheric burner with a power of 38, 44, 50, 55 kW.
A new generation of time-tested boilers with modern EMS Plus automation and industrial design from Buderus.
Modern universal boiler concept Buderus Logano G234 WS
- Low-temperature heating boiler according to DIN EN 297 for continuously regulating the boiler water temperature without a base temperature (minimum boiler water temperature)
- Four certified boiler sizes with rated heating output from 38 to 55 kW
- The heating boiler is designed to operate on natural gas H or liquefied gas P /B/P
- Boiler design with perfectly fitted sections made of high-quality cast iron
- Tested and reliable heating boiler with cast iron heat exchanger and atmospheric gas burner
- Combines with adjacent Logalux SU water heater tanks from the Buderus program
- Can be combined with various EMS and EMS Plus control systems from the Buderus program
- New "industrial" design from Buderus
- High standardized utilization rate (92%) and low emissions of harmful substances
Quiet and reliable operation
- Atmospheric gas burner with pre-mixing without fan
- Heating mode without additional noise reduction measures
- Stable operation on natural gas with supply pressure up to 10 mbar
Simple and convenient control with modern weather-compensated automation Logamatic MC110 standard EMS Plus
- System controller RC310 or BC30E with touch display and full text menu
- Readable text, symbols, status and error information
- Control functions coordinated with the plant hydraulics
- Simple step-by-step and intuitive setup of all control system functions
- It is possible to expand the configuration of the control system with additional modules:
- KM200 module for remote control via the Internet
- Mixing module MM100
- Cascade module MC400 with the ability to control up to 4 boilers
- For complex systems, we recommend using the new generation of professional automation Logamatic 5000
Quick installation, commissioning and maintenance of the Buderus Logano G234WS boiler
- A system for quickly installing the heating circuit, adapted to the corresponding hydraulic circuit, for connecting it to the boiler or mounting it to the wall
- Convenient connection of Logalux SU water heater tanks with a capacity of 120, 160, 200 and 300 liters to the boiler thanks to the boiler-water heater connecting pipeline with loading pump and check valve
- Burner design without moving parts
- Easy conversion of the burner to other types of gas
Description
Buderus Logano G234-50 WS (RU TOP) is a gas floor-standing boiler equipped with an atmospheric burner and intended for use in premises for various purposes. Using natural gas of group H or liquefied gas of groups P / B / P as fuel, this unit easily copes with the tasks of heating or hot water supply in country houses, warehouses and industrial premises with a high efficiency - up to 90-92%.
Buderus Logano G234-50 WS (RU TOP) is a 2017 model with a new modern design. The side panels and control system housing are finished in classic blue, while the front and top panels are a rich, deep dark color. The size of the boiler has been reduced, which allows it to be placed in almost any convenient place without damaging the interior.
Some functional and technical features of the boiler have also been improved. The Logamatic MC110 automation of the EMS Plus standard allows you to control the heating circuit using a weather-dependent mode and expand the functionality through additional modules. The improved SAFe burner control will allow the boiler to reach a new level of efficiency and reliability.
Advantages of the gas boiler Buderus Logano G234-50 WS (RU TOP)
Quiet and reliable operation. The boiler has an atmospheric gas burner with pre-mixing without a fan. It is highly reliable and operates extremely quietly. For comfortable operation of the Buderus Logano G234-50 WS (RU TOP) no additional noise reduction measures are required. The boiler operates stably with the specified performance indicators using natural gas with a supply pressure of up to 10 mbar.
Simple and convenient controls. An important innovation of this model is the presence of modern weather-compensated automation: Logamatic MC110 standard EMS Plus, as well as a system controller RC310 or BC30E with a touch-screen and full-text menu. The display provides easy-to-read text, symbols, status and error information. There is a simple step-by-step and intuitive setup of all functions of the control system - understanding the basics of controlling the Buderus Logano G234-50 WS (RU TOP) boiler is not difficult.
Possibility of modernization. The boiler configuration can be expanded with additional options:
- KM200 module for remote control via the Internet;
- mixing module MM100;
- cascade module MC400 with the ability to control up to four boilers;
- For complex systems, it is possible to connect professional automation of the new generation Logamatic 5000.
Quick installation and commissioning. The system for quick installation of the heating circuit Buderus Logano G234-50 WS (RU TOP) is adapted to the corresponding hydraulic circuit. Thanks to this, installation of the boiler is quick and does not require lengthy preparation stages. The water heater tank is easily connected to the boiler via a connecting pipeline with a loading pump and a check valve. The burner design does not contain moving parts; if necessary, it can be adjusted to other types of gas.
High build quality. Production is carried out in Germany using original developments and the best materials. At all stages of creating finished products, strict quality control is carried out, which ensures a high level of quality for Buderus Logano G234-50 WS (RU TOP). The emission level of harmful substances is extremely low and meets modern European standards.
You can find out additional information about this equipment and order a floor-standing gas boiler Buderus Logano G234-50 WS (RU TOP) on our website or from the sales department.